Creating FTA Files
Prerequisites: a SOX project was created and the Repository view is active.
Â
In the Repository view, right-click on the FTA folder.
Choose New > New FTA File. - Outcome: The "New FTA file" dialog will open.
Click on Browse... to choose the target folder to which you wish to save the FTA file.
Choose a file name for the FTA file.
Choose the Mission Time (in hours) for this FTA.
Assign a Safety Goal for the FTA file. (Can be assigned later)
Assigned hazards can be selected with a check mark. (Can be assigned later)
 Outcome: An FTA file was created and added to the repository.
Now you can drag and drop the objects from the sidebar to form a fault tree, derive an FTA from an FMEA or use single failures and components from the FMEA out of the PSS view.
Â