Synchronization With FMEA
This function provides semi-automatic support for synchronization of FMEDA system effects and hardware failures with FMEA. After activating the Sync function, the following analyses will be executed by SOX.
Empty hardware effect
Empty system effect
Not safety-related system effect
Missing system effect
In this example, the hardware failure (MF10) effects three system failures (MF1, MF58, MF2) as can be seen from the FMEA failure net. However, MF58 is missing at the FMEDA. This will be recognized by the synchronization with the FMEA function.
Hardware effect not assigned to module
Missing hardware effect
Prerequisites: an FMEDA and an FMEA were created.
Go to the Repository view and right-click on the desired FMEDA.
Choose Sync with FMEA. - Outcome: the “FMEA Selection” dialog will open.
Select your target FMEA and click on Next. - Outcome: the “Analysis Results” dialog will open.
[1] In this area you can drag columns. Same messages of the dragged column will be grouped. With a right-click on a dragged column you can ungroup the messages.
[2] In this area the results of the analyses are displayed.
[3]
• Toggle Group By Header
Shows or hides the area [1] for dragging columns to group.
• Collapse All
Collapse all expanded groups.
• Expand All
Expand all collapsed groups.
• Export
Export the analysis results as an Excel Workbook (.xls).
• Refresh
Refresh the analysis results. This can be necessary by editing the FMEDA while this dialog is
active.Select your desired results, right-click and choose Quick Fix. The selection made in this dialog triggers a selection in the editor or PSS. - Outcome: the “Quick Fix” dialog will open.
Select the desired changes and click OK. - Outcome: the selected changes will be added to the FMEDA.